Wood floor finishing can expose workers, building occupants and homeowners to fire hazards: in Massachusetts, three floor sanders died in two fires when the flammable lacquer sealer they were using caught fire.1 Massachusetts bans selling lacquer sealers with a flashpoint below 100 degrees Fahrenheit for commercial wood floor finishing, and bans floor finishing businesses from using them.2
Why are floor refinishing fires so dangerous?
Wood floor sanding and finishing can be hazardous to workers and building occupants, and in Boston more than 25 fires were directly attributed to wood floor installation and refinishing from 1995 to 2004.3 The lacquer sealer used in the two fatal Massachusetts fires was highly flammable, with a flash point of 9 degrees F (minus 13 degrees C).1
In both of those fires, the lacquer sealer the workers were applying was ignited by a gas pilot light: in a gas stove in one house, and on a gas hot water heater in the other. The hot water heater was located in a closet on the same level of the house where the floors were being finished. At the time of each fire, windows were closed and no other means of ventilation were being used, though the front door was open in the second house.1
What did the Massachusetts floor sander death investigations find?
The Massachusetts deaths were studied through Fatality Assessment and Control Evaluation (FACE) reports.3-4 FACE is a research program, and FACE investigators do not enforce compliance with state or federal occupational safety and health standards and do not determine fault or blame.3
In the first Massachusetts incident, two floor sanders died from burns and two were seriously burned while refinishing wood floors in a three-family house. In the second incident, one floor sander died from burns and another received minor burns while finishing wood floors they had installed in a single family house. All three of the workers who died were Vietnamese immigrants.1
On July 2, 2005, a 43-year-old floor sander was fatally injured when the one story single family house he was working in caught fire. The floor sander and a co-worker had just finished installing hardwood floors and were finishing them when the flammable lacquer floor sealer they were applying ignited and the house caught fire. The victim was pronounced dead at the scene, and the co-worker was able to exit the house without injuries.4
The floor finishing industry in Massachusetts is largely dominated by the immigrant Vietnamese community, and in response to the deaths several prevention measures were instituted, including culturally specific training and laws requiring permits and banning highly flammable lacquer sealers.3
Which floor sealers are banned in Massachusetts?
Under Massachusetts General Laws chapter 94, section 329, a lacquer sealer is a clear or pigmented wood finish, formulated with nitrocellulose or synthetic resins to dry by evaporation and without chemical reaction, that has a flashpoint below 100 degrees Fahrenheit, and the term includes clear lacquer sanding sealers. A commercial wood floor finishing operation is the sanding of wood floors and the application of a floor finishing product, altering the wood surface for purposes directly or indirectly connected with any business or other undertaking intended for profit. A floor finishing product is any substance formulated, marketed or otherwise intended for use to seal or coat wood with a protective finish by a floor finishing operation.2
Subsection (b) of section 329 bars any manufacturer, wholesale dealer, agent or person from selling, keeping, offering for sale, or having in his possession or under his control a lacquer sealer for any commercial wood floor finishing operation. Subsection (c) bars any person, co-partnership, corporation or association in the business of applying a penetrating sealant or liquid coating to the surface of a wood floor from using a lacquer sealer while engaged in a commercial wood floor finishing operation. The ban in section 329 is Massachusetts law, and it applies to commercial wood floor finishing operations as the section defines them.2
What are the penalties under Massachusetts General Laws chapter 94, section 329?
Section 329 is titled "Sale, possession or use of lacquer sealer prohibited; penalties". A violation of the sale and possession ban in subsection (b) is punished by a fine of not less than $2,500. For a second or subsequent violation of subsection (b), the penalty is a fine of not less than $5,000 or imprisonment in the house of correction for not more than 1 year or both. A floor finishing business that uses a lacquer sealer in a commercial wood floor finishing operation faces the same penalties under subsection (c): a fine of not less than $2,500 and, for a second or subsequent violation, a fine of not less than $5,000 or imprisonment in the house of correction for not more than 1 year or both.2
How can floor finishing fires be prevented?
The Massachusetts FACE Program concluded that employers should use wood floor finishing products that are less flammable (products with flash points greater than 100 degrees F) for indoor applications. Employers should also ensure that work areas are adequately ventilated during indoor application of wood floor finishing products and that ignition sources including gas pilot lights are extinguished before work begins, and should conduct job hazard analyses with a safety checklist completed before work begins. A written hazard communication program that trains employees about the chemicals they work with and the hazards and controls of those chemicals is on the same employer list.4
Homeowners finishing wood floors themselves or through hired contractors should ensure that only less flammable floor finishing products (products with flash points greater than 100 degrees F) are used inside their homes. The same report recommended that policymakers consider developing regulatory approaches to minimize the risk of fires and explosions during wood floor finishing.4
The Massachusetts Department of Public Health's report on the two fires calls for extinguishing all open flames and other ignition sources before beginning work, including gas appliance pilots on stoves, hot water heaters, heating units and clothes dryers. Cycling electrical appliances such as refrigerators and air conditioners should be turned off and unplugged, light switches shouldn't be turned on or off during the floor finishing process, and power to the work area should be turned off if possible. Work areas should be adequately ventilated during wood floor finishing, with windows open and kept open during product application until the product is dry, and electric fans used for ventilation must be classified as explosion proof and be plugged in outside of the work area.1
How do oily rags start fires?
Spontaneous combustion, often called spontaneous ignition, is the occurrence of fire without the application of an external heat source. In spontaneous combustion, chemical, biological or physical processes make combustible materials self-heat to a temperature high enough for ignition to occur. Rags and towels soaked with oils such as cooking, linseed or motor oils can spontaneously combust under the right conditions, and the fire can spread to nearby combustibles and cause severe damage, building loss, and injuries to building occupants and firefighters.5
Improper laundering and storage of grease and oil-soaked rags and towels caused seven reported incidents of spontaneous combustion in National Park Service concession kitchens and buildings under renovation over two years. In one of those incidents, a milk crate of oil-soaked rags was found on a kitchen table, and once the crate was carried outside it ignited in the hands of a firefighter.5
Prevention of spontaneous combustion begins with good housekeeping practices, and oil-soaked rags and towels should never be stored in a pile. The National Park Service alert calls for pre-soaking rags and towels to remove as much oil as possible before laundering, removing them from the dryer as soon as the cycle is over or hanging them to dry, and letting them dry and cool before folding and stacking. Standard washers, dryers and detergents are not capable of effectively removing grease from rags and towels, and the alert calls for using only commercial-grade appliances and detergents designed to clean oil-soaked rags. Clean rags and towels go in metal cabinets, and dirty rags go in certified metal containers with self-closing lids, away from heat sources such as furnaces and water heaters.5
NIOSH and Massachusetts FACE fatality reports, Massachusetts General Laws chapter 94, section 329, and a National Park Service fire alert, checked November 2026.
Sources (5)
- Massachusetts Department of Public Health: Wood Floor Sanders Killed When Floor Finishing Product Catches Fire - Massachusetts, read November 25, 2026 ↑
- Massachusetts Legislature: General Law - Part I, Title XV, Chapter 94, Section 329, read November 25, 2026 ↑
- National Institute for Occupational Safety and Health: Learning from Workplace Fatality Investigations, read November 25, 2026 ↑
- National Institute for Occupational Safety and Health: Floor Sander Dies When Wood Floor Refinish Product Ignites - Massachusetts: Report 05-MA-044, read November 25, 2026 ↑
- National Park Service: Structural Fire Alert, read November 25, 2026 ↑